CV-4-002

Agreement on use of Local Relative Placement

Based on          IFC4

Initiator            ISG Meeting-Prague

Effects              Reference View & Design Transfer View

Date                    2013 09 13

Description:

Local Relative placement shall NOT contain georeference data;

Z value of the Storey local relative Placement shall reflect the intended Storey elevation;

For all other elements it is recommended for Local Relative Placement to be located within the bounding box;

Absolute value shall not exceed the limits of the overall building bounding box multiplied by 2.